1 | Changelog APPH GUI | |||||||
---|---|---|---|---|---|---|---|---|
2 | ||||||||
3 | Date | Revision | Changed | |||||
4 | 17.10.2023 | 1.3.22 | Redesign of GUI settings saving/loading Add support for dual down converter boxes for FN measurement Add "unwrap phase" function to Transient Analysis Improve device communication Stabilize TSTAB file streaming | |||||
5 | 21.07.2023 | 1.3.21 | Improved Device Search | |||||
6 | 06.07.2023 | 1.3.20 | Added a new security measurement Improved Firmware Update feature Fixed bug with amplitude measurement result retrieval - only with FW >0.4.180 Fixed beat alignment issue at 6.25 GHz Fixed connection dialog crash Continuous mode handles changing carrier frequencies without manual interaction | |||||
7 | 26.05.2023 | 1.3.19 | improved connection stability (both USB and ethernet) | |||||
8 | 21.12.2022 | 1.3.18 | adjust absolute phase noise - high drift mode added feature to save spurs minor bug fixes | |||||
9 | 20.07.2022 | 1.3.17 | improve stability of measurement fix freeze during startup after software update (rare) fix visual glitch for unselection of traces | |||||
10 | 06.04.2022 | 1.3.16 | add down conversion mode for option LO in "High Drift" tab rework external references tuning sensitivity measurement add "contact support" dialog improve responsiveness of GUI | |||||
11 | 14.12.2021 | 1.3.14 | reenable manual firmware upload and add firmware compatibility check improve USB communications fix bug with FFT Analyzer units snap markers to spurs | |||||
12 | 22.11.2021 | 1.3.13 | improved trigger UI for transient analysis
added self test to menu minor bugfixes | |||||
13 | 28.09.2021 | 1.3.12 | improvement of additive PN workflow
adjusted TSTAB tau-range fix check for GUI update on startup and add Help->Update GUI if available | |||||
14 | 06.07.2021 | 1.3.11 | improved additive phase noise workflow minor bugfixes | |||||
15 | 14.04.2021 | 1.3.8 | fix USB detection on new installations | |||||
16 | 11.03.2021 | 1.3.7 | fix for option SPEC for frequencies < 1 GHz | |||||
18 | 14.09.2020 | 1.2.112 | Layout adjustments Improvement of additive phase noise measurement process Introduction of signal detection ranges Extension of measureable pulse parameter range Selection screen for saving of data | |||||
19 | 27.03.2020 | 1.2.102 | Introduction of option LO to configure outputs Support of new hardware platforms Minor changes in visual appearance and handling of plots Fixed issue with calibration for Spectrum Monitoring for older devices | |||||
20 | 22.01.2020 | 1.2.100 | Fixed a rare error in the signal detection before a measurement Saving data to network drives is now faster Import/export of traces in XML and CSV format Transfer traces between tabs from within the GUI | |||||
21 | 07.11.2019 | 1.2.96 | Introduced option to clear user data from device Supports new hardware platform | |||||
23 | 18.07.2019 | 1.2.94 | Redesign of communication code Fixed a bug that sometimes didn't save the PDF report correctly Added possibility to stream frequency data into file during time stability measurement Added warning before overwriting files Burst mode measurements can now be saved through the menu | |||||
24 | 15.04.2019 | 1.2.91 | VCO characterization improvement of measurement speed Rework of spectrum analysis (scanning, RBW, VBW, markers) Bugfixes for communication stability | |||||
25 | 21.12.2018 | 1.2.90 | Extension of data export; csv, xls and mat for all measurement modes | |||||
26 | 21.11.2018 | 1.2.89 | License file handling has been introduced some improvements for the newer modes (more to come) Support of latest hardware has been extended | |||||
27 | 06.07.2018 | 1.2.85 | UI has been rearranged to make more space for plot results Cleaner UI, easier handling Redesign of additive phase noise measurement Fixed an issue regarding the transient analysis of the idle mode in pulsed signals Detection of pulsed signals | |||||
28 | 20.04.2018 | 1.2.83 | Added support for the new hardware versions Added AM pulsed measurement Added Burst mode measurement Improved signal detection Improved measurement algorithm | |||||
29 | 28.09.2017 | 1.2.74 | Performance improvements with multiple traces Limits number of visible datapoints (prevent slow down) Improved measurement speed Improved Residual Phase Noise user interface | |||||
30 | 11.09.2017 | 1.2.72 | Improvements for new hardware First implementation for time stability mode Added meta data to excel export Various bugfixes Removed older unused measurement modes Redesign of statistics tab Performance improvements Fixed locking issues with new hardware (>=0270) | |||||
31 | 19.06.2017 | 1.2.67 | Full support of new HW platform (serials ending in >0270) Full support of the new 40 GHz SSA Improved measurement with external reference Adjustments of the user interface Improved communication speeds and stability Improved spur detection and visualization Added full resolution spurs | |||||
32 | 16.03.2017 | 1.2.63 | Implementations for new design and GUI revision Added Amplitude Noise capabilities for new design Added High Drift Phase Noise capabilities for new design Revised transient analysis for new design Revised spectrum monitoring for new design Added "automatic Kphi" mode for Additive Phase Noise | |||||
33 | 19.12.2016 | 1.2.60 | Added scaling options when saving plot as PNG Reintroduced Spectrum Monitoring tab Introduced Amplitude Noise mode for new design (2017) | |||||
34 | 22.09.2016 | 1.2.59 | Introduced some plot features (larger font, save with specific aspect ratio, etc) Improved spur detection algorithm Improved locking algorithm | |||||
35 | 18.08.2016 | 1.2.57 | Fixed residual PM data bug Added video filter to Transient Analysis Added narrowband span support to Transient Analysis Various changes for Transient Analysis Improved Pulsed RF Measurement | |||||
36 | 15.06.2016 | 1.2.52 | Various changes in Transient Analysis Cleaned up relative noise floor display | |||||
37 | 20.05.2016 | 1.2.50 | Improved support for older units | |||||
38 | 20.05.2016 | 1.2.49 | Network Config DHCP Auto mode Updated schematics Refurbished relative measurement noise floor | |||||
39 | 30.03.2016 | 1.2.47 | Reintroduce transient narrowband Introduced pulsed additive phase noise Improved LN locking | |||||
40 | 24.02.2016 | 1.2.45 | Measurement of pulsed RF signals | |||||
42 | 28.01.2016 | 1.2.43 | Fixes in connection protocol | |||||
44 | 24.12.2015 | 1.2.41 | Stoppable measurements (FW 0.4.66) Fixes in Transient Analysis Changes in VCO Characterization | |||||
45 | 04.12.2015 | 1.2.40 | Service mode for AP technicians | |||||
46 | 02.12.2015 | 1.2.39 | Voltage settings fixed UI fixes Rewritten VCO Characterization | |||||
47 | 19.11.2015 | 1.2.38 | Support for new unit hardware Ext trigger for transient analysis Ext reference 10M for counter Introduced spur setting "Raw" Increased jitter integration range UI fixes Spectrum monitoring tab | |||||
48 | 29.09.2015 | 1.2.37 | Ext Kphi read optimized Ext sensitivity manually settable | |||||
49 | 22.09.2015 | 1.2.36 | Signal search for Additive Improved locking algorithm | |||||
50 | 16.09.2015 | 1.2.35 | Voltage settings fixed (rounding) Improved Kphi detection (older units) UI changes for VCO Characterization | |||||
51 | 02.09.2015 | 1.2.34 | UI changes (plot rendering) Baseband measurement fixed | |||||
53 | 22.07.2015 | 1.2.30 1.2.31 1.2.32 | Periodic save of GUI configuration Info in plot window (PLL BW, Kvco, sens, etc) Introduced raw spurs Improved frequency search | |||||
54 | 12.06.2015 | 1.2.29 | Markers draggable from outside | |||||
55 | 03.06.2015 | 1.2.29b1 | UI fixes | |||||
56 | 01.06.2015 | 1.2.28 | DUT supply in Additive / Transient UI fixes Improved locking <30 MHz |